We investigated the rotational harmonic source of the runout in a 2.5″ hard disk drive (HDD) with a height of 5 mm, especially at low rotating speeds. After disassembling the HDD, circumferential scratches between the upper thrust surface of the hub and sleeve were observed. Through a finite element static analysis of the hub, the deflection result...