Log in to save to my catalogue

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_199ff0e542084456973df0375fc54912

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

About this item

Full title

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

Publisher

Berlin/Heidelberg: Springer Berlin Heidelberg

Journal title

The European physical journal. C, Particles and fields, 2024-10, Vol.84 (10), p.1004-14, Article 1004

Language

English

Formats

Publication information

Publisher

Berlin/Heidelberg: Springer Berlin Heidelberg

More information

Scope and Contents

Contents

The DUNE far detector has been designed to detect photons and electrons generated by the charged products of the interaction of neutrinos with a massive liquid argon (LAr) target. The photon detection system (PDS) of the first DUNE far detector (FD1) is composed of 6000 photon detection units, named
X-ARAPUCA
. The detection of the prompt light pulse generated by the particle energy release in LAr will complement and boost the DUNE LAr Time Projection Chamber. It will improve the non-beam events tagging and enable at low energies the trigger and the calorimetry of the supernova neutrinos. The X-ARAPUCA is an assembly of several components. Its photon detection efficiency (PDE) depends on the design of the assembly, on the grade of the individual components and on their coupling. The X-ARAPUCA PDE is one of the leading parameters for the PDS sensitivity, that in turn determines the sensitivity of the DUNE for the detection of core-collapse supernova within the galaxy and for nucleon decay searches. In this work we present the final assessment of the absolute PDE of the FD1 X-ARAPUCA baseline design, measured in two laboratories with independent methods and setups. Preliminary results were reported in Palomares (JINST 18(02):C02064,
https://doi.org/10.1088/1748-0221/18/02/C02064
, 2023). One hundred sixty units of these X-ARAPUCA devices have been deployed in the NP04 facility at the CERN Neutrino Platform, the 1:20 scale FD1 prototype, and will be operated during the year 2024. The assessed value of the PDE is a key parameter both in the NP04 and in the DUNE analysis and reconstruction studies....

Alternative Titles

Full title

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_doaj_primary_oai_doaj_org_article_199ff0e542084456973df0375fc54912

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_199ff0e542084456973df0375fc54912

Other Identifiers

ISSN

1434-6052,1434-6044

E-ISSN

1434-6052

DOI

10.1140/epjc/s10052-024-13393-2

How to access this item