Feasibility of cardiac output measurements in critically ill patients by medical students
Feasibility of cardiac output measurements in critically ill patients by medical students
About this item
Full title
Author / Creator
Publisher
Milan: Springer Milan
Journal title
Language
English
Formats
Publication information
Publisher
Milan: Springer Milan
Subjects
More information
Scope and Contents
Contents
Background
Critical care ultrasonography (CCUS) is increasingly applied also in the intensive care unit (ICU) and performed by non-experts, including even medical students. There is limited data on the training efforts necessary for novices to attain images of sufficient quality. There is no data on medical students performing CCUS for the measurement of cardiac output (CO), a hemodynamic variable of importance for daily critical care.
Objective
The aim of this study was to explore the agreement of cardiac output measurements as well as the quality of images obtained by medical students in critically ill patients compared to the measurements obtained by experts in these images.
Methods
In a prospective observational cohort study, all acutely admitted adults with an expected ICU stay over 24 h were included. CCUS was performed by students within 24 h of admission. CCUS included the images required to measure the CO, i.e., the left ventricular outflow tract (LVOT) diameter and the velocity time integral (VTI) in the LVOT. Echocardiography experts were involved in the evaluation of the quality of images obtained and the quality of the CO measurements.
Results
There was an opportunity for a CCUS attempt in 1155 of the 1212 eligible patients (95%) and in 1075 of the 1212 patients (89%) CCUS examination was performed by medical students. In 871 out of 1075 patients (81%) medical students measured CO. Experts measured CO in 783 patients (73%). In 760 patients (71%) CO was measured by both which allowed for comparison; bias of CO was 0.0 L min
−1
with limits of agreement of − 2.6 L min
−1
to 2.7 L min
−1
. The percentage error was 50%, reflecting poor agreement of the CO measurement by students compared with the experts CO measurement.
Conclusions
Medical students seem capable of obtaining sufficient quality CCUS images for CO measurement in the majority of critically ill patients. Measurements of CO by medical students, however, had poor agreement with expert measurements. Experts remain indispensable for reliable CO measurements.
Trial registration
Clinicaltrials.gov;
http://www.clinicaltrials.gov
; registration number NCT02912624...
Alternative Titles
Full title
Feasibility of cardiac output measurements in critically ill patients by medical students
Authors, Artists and Contributors
Identifiers
Primary Identifiers
Record Identifier
TN_cdi_doaj_primary_oai_doaj_org_article_2775aa4b58bc4ae68d8d02e6bb095003
Permalink
https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_2775aa4b58bc4ae68d8d02e6bb095003
Other Identifiers
ISSN
2524-8987
E-ISSN
2524-8987
DOI
10.1186/s13089-020-0152-5