Contents
This brief proposes a calibration method for offset, gain, and timing‐skew mismatches in time‐interleaved analog‐to‐digital converters. The calibration method includes the estimation method and the correction method. The estimation method is based on the difference between the spectral distribution of the error harmonics and the input signal. The c...