Log in to save to my catalogue

Temperature Changes (Δ T ) in Correlation with Number of Implant Osteotomy Preparations in Human Cad...

Temperature Changes (Δ T ) in Correlation with Number of Implant Osteotomy Preparations in Human Cad...

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_6782f02a51a641cc9e0d9c9a0e64b75f

Temperature Changes (Δ T ) in Correlation with Number of Implant Osteotomy Preparations in Human Cadaver Tibiae, Comparing Osseodensification (OD) Burs in Clockwise (CW) versus Counterclockwise (CCW) Mode

About this item

Full title

Temperature Changes (Δ T ) in Correlation with Number of Implant Osteotomy Preparations in Human Cadaver Tibiae, Comparing Osseodensification (OD) Burs in Clockwise (CW) versus Counterclockwise (CCW) Mode

Publisher

Switzerland: MDPI AG

Journal title

Journal of functional biomaterials, 2024-08, Vol.15 (8), p.237

Language

English

Formats

Publication information

Publisher

Switzerland: MDPI AG

More information

Scope and Contents

Contents

(1) Background: OD burs are used in two different modes: (i) CW and (ii) CCW. The purpose of the study was to evaluate the Δ
during the preparation of implant osteotomies in a four-way interaction. (2) Methods: Three hundred and sixty osteotomies were prepared at 12 mm depth in human cadaver tibiae. The Δ
values were calculated similarly to t...

Alternative Titles

Full title

Temperature Changes (Δ T ) in Correlation with Number of Implant Osteotomy Preparations in Human Cadaver Tibiae, Comparing Osseodensification (OD) Burs in Clockwise (CW) versus Counterclockwise (CCW) Mode

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_doaj_primary_oai_doaj_org_article_6782f02a51a641cc9e0d9c9a0e64b75f

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_6782f02a51a641cc9e0d9c9a0e64b75f

Other Identifiers

ISSN

2079-4983

E-ISSN

2079-4983

DOI

10.3390/jfb15080237

How to access this item