Log in to save to my catalogue

Novel minimally invasive carpal tunnel release using a specialized surgical kit: a prospective multi...

Novel minimally invasive carpal tunnel release using a specialized surgical kit: a prospective multi...

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_6d3c4569c336429482a6fc37687db704

Novel minimally invasive carpal tunnel release using a specialized surgical kit: a prospective multi-center case series

About this item

Full title

Novel minimally invasive carpal tunnel release using a specialized surgical kit: a prospective multi-center case series

Publisher

England: BioMed Central Ltd

Journal title

BMC musculoskeletal disorders, 2025-04, Vol.26 (1), p.346-11, Article 346

Language

English

Formats

Publication information

Publisher

England: BioMed Central Ltd

More information

Scope and Contents

Contents

Carpal tunnel syndrome (CTS) is the most common peripheral nerve compression neuropathy. While established surgical techniques have demonstrated reliable outcomes and safety profiles, innovations in minimally invasive approached continue to emerge. This study evaluates a novel minimally invasive surgical technique using a specialized instrument for carpal tunnel release.
In this prospective multi-center case series, 41 patients underwent minimally invasive carpal tunnel release using a novel surgical kit. Outcomes were assessed through Visual Analog Scale (VAS), Boston Carpal Tunnel Questionnaire (BCTQ), grip and pinch strength measurements, and nerve conduction velocity (NCV) testing at regular intervals over 24 weeks post-surgery.
Mean surgical time was 7.02 min. Significant improvements were observed in VAS scores (LS-Mean - 0.57, P < 0.0001) and BCTQ scores (Symptom Severity: LS-Mean - 2.62, P < 0.0001; Functional Status: LS-Mean - 1.20, P < 0.0001) by 24 weeks. Grip and pinch strengths showed significant improvement from 2 weeks post-surgery. Mean time to return to work was 18.2 days. NCV testing demonstrated significant improvements in both latency (LS-Mean - 0.57, P < 0.0001) and velocity (LS-Mean 5.79, P < 0.0001). One superficial infection and two cases of temporary numbness were reported, with no recurrent CTS observed.
This novel minimally invasive technique demonstrates promising clinical outcomes with shortened operative time, rapid symptom relief, and early functional recovery. While larger randomized studies are needed, these preliminary findings suggest this technique may be a valuable addition to current surgical options for CTS.
Clinicaltrials.gov, NCT05067205. Prospectively registered, date of first registration: 05/10/2021 ( https://clinicaltrials.gov/study/NCT05067205 )....

Alternative Titles

Full title

Novel minimally invasive carpal tunnel release using a specialized surgical kit: a prospective multi-center case series

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_doaj_primary_oai_doaj_org_article_6d3c4569c336429482a6fc37687db704

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_6d3c4569c336429482a6fc37687db704

Other Identifiers

ISSN

1471-2474

E-ISSN

1471-2474

DOI

10.1186/s12891-025-08612-0

How to access this item