Log in to save to my catalogue

Improving Structural Safety of L-Type Flange Joint for Wind Towers

Improving Structural Safety of L-Type Flange Joint for Wind Towers

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_doaj_primary_oai_doaj_org_article_a288b13c3c7f478c94b65f4d0cf76e54

Improving Structural Safety of L-Type Flange Joint for Wind Towers

About this item

Full title

Improving Structural Safety of L-Type Flange Joint for Wind Towers

Publisher

Basel: MDPI AG

Journal title

Energies (Basel), 2022-12, Vol.15 (23), p.8967

Language

English

Formats

Publication information

Publisher

Basel: MDPI AG

More information

Scope and Contents

Contents

This paper focuses on the design modification of L-type flange joint geometry in wind towers, aiming to enhance its structural safety. For this aim, current design issues of existing flange joints are discussed. The numerical simulations indicate that the threaded bolt and flange-to-shell junction are critical locations where failure may happen. Fu...