Log in to save to my catalogue

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a h...

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a h...

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_proquest_journals_2215417660

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound

About this item

Full title

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound

Publisher

Berlin/Heidelberg: Springer Berlin Heidelberg

Journal title

European radiology, 2019-11, Vol.29 (11), p.6129-6139

Language

English

Formats

Publication information

Publisher

Berlin/Heidelberg: Springer Berlin Heidelberg

More information

Scope and Contents

Contents

Objectives
We sought to evaluate the accuracy of standardized total plaque volume (TPV) measurement and low-density non-calcified plaque (LDNCP) assessment from coronary CT angiography (CTA) in comparison with intravascular ultrasound (IVUS).
Methods
We analyzed 118 plaques without extensive calcifications from 77 consecutive patients who...

Alternative Titles

Full title

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_proquest_journals_2215417660

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_proquest_journals_2215417660

Other Identifiers

ISSN

0938-7994

E-ISSN

1432-1084

DOI

10.1007/s00330-019-06219-3