Log in to save to my catalogue

3-year follow-up of a prospective, multicenter study of the Amplatzer Piccolo™ Occluder for transcat...

3-year follow-up of a prospective, multicenter study of the Amplatzer Piccolo™ Occluder for transcat...

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10541325

3-year follow-up of a prospective, multicenter study of the Amplatzer Piccolo™ Occluder for transcatheter patent ductus arteriosus closure in children ≥ 700 grams

About this item

Full title

3-year follow-up of a prospective, multicenter study of the Amplatzer Piccolo™ Occluder for transcatheter patent ductus arteriosus closure in children ≥ 700 grams

Publisher

New York: Nature Publishing Group US

Journal title

Journal of perinatology, 2023-10, Vol.43 (10), p.1238-1244

Language

English

Formats

Publication information

Publisher

New York: Nature Publishing Group US

More information

Scope and Contents

Contents

Objective
This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder.
Study Design
Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or pro...

Alternative Titles

Full title

3-year follow-up of a prospective, multicenter study of the Amplatzer Piccolo™ Occluder for transcatheter patent ductus arteriosus closure in children ≥ 700 grams

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10541325

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10541325

Other Identifiers

ISSN

0743-8346

E-ISSN

1476-5543

DOI

10.1038/s41372-023-01741-1

How to access this item