Regional variations in patient selection and procedural characteristics for cryoballoon ablation of...
Regional variations in patient selection and procedural characteristics for cryoballoon ablation of atrial fibrillation in the cryo global registry
About this item
Full title
Author / Creator
Cryo Global Registry Investigators , On behalf of the Cryo Global Registry Investigators , Scazzuso, Fernando , Ptaszyński, Paweł , Kaczmarek, Krzysztof , Chun, K. R. Julian , Khelae, Surinder Kaur , Földesi, Csaba , Obidigbo, Valentine , van Bragt, Kelly A. , On, Young Keun , Al-Kandari, Fawzia and Okumura, Ken
Publisher
New York: Springer US
Journal title
Language
English
Formats
Publication information
Publisher
New York: Springer US
Subjects
More information
Scope and Contents
Contents
Background
Cryoballoon ablation is a well-established anatomical approach for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Although widely adopted, regional variations in standards of care have not been well characterized.
Methods
Patients with AF were enrolled in the Cryo Global Registry (NCT02752737) from May 2016 to Sept 2021 at 128 sites in 37 countries and treated with cryoballoon ablation according to local clinical practice. Baseline patient and procedural characteristics were summarized for 8 regions (Central Asia & Russia, East Asia, Europe, Middle East, North America, South Africa, South America, and Southeast Asia). Serious procedure-related adverse events (SAEs) were evaluated in a subset of patients with ≥ 7 days of follow-up.
Results
A total of 3,680 patients undergoing initial PVI for AF were included. Cryoballoon ablation was commonly performed in patients with paroxysmal AF. Mean age ranged from 47 ± 12 years in the Middle East to 64 ± 11 years in East Asia. Mean procedure time was ≤ 95 min in all regions. Average freeze duration ranged from 153 ± 41 s in Southeast Asia to 230 ± 29 s in Central Asia & Russia. Acute procedural success was ≥ 94.7% in all geographies. In 3,126 subjects with ≥ 7 days of follow-up, 122 procedure-related SAEs were reported in 111 patients (3.6%) and remained low in all regions. One procedure-related death was reported during data collection.
Conclusions
Despite regional variations in patient selection and procedural characteristics, PVI using cryoballoon ablation was performed with high acute success and short procedural times around the world.
Clinical trial registration
https://clinicaltrials.gov/ct2/show/NCT02752737
Graphical Abstract...
Alternative Titles
Full title
Regional variations in patient selection and procedural characteristics for cryoballoon ablation of atrial fibrillation in the cryo global registry
Authors, Artists and Contributors
Author / Creator
Identifiers
Primary Identifiers
Record Identifier
TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11016010
Permalink
https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11016010
Other Identifiers
ISSN
1572-8595,1383-875X
E-ISSN
1572-8595
DOI
10.1007/s10840-023-01582-0