Accidental spinal cord injury during spinal anesthesia: A report

Accidental spinal cord injury during spinal anesthesia: A report

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3021935

Accidental spinal cord injury during spinal anesthesia: A report

About this item

Full title

Accidental spinal cord injury during spinal anesthesia: A report

Publisher

India: Medknow Publications and Media Pvt. Ltd

Journal title

Annals of the Indian Academy of Neurology, 2010-10, Vol.13 (4), p.297-298

Language

English

Formats

Publication information

Publisher

India: Medknow Publications and Media Pvt. Ltd

More information

Scope and Contents

Contents

The injection was initially at L 1 -L 2 site using a 25-gauge spinal needle. Since there was no free flow of cerebrospinal fluid, second attempt was made at T 12 -L 1 interspace. [...] it could not be ascertained whether the radiating pain was during the needle prick or during the injection of local anesthetic.