Log in to save to my catalogue

A dataset of clinically recorded radar vital signs with synchronised reference sensor signals

A dataset of clinically recorded radar vital signs with synchronised reference sensor signals

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7479598

A dataset of clinically recorded radar vital signs with synchronised reference sensor signals

About this item

Full title

A dataset of clinically recorded radar vital signs with synchronised reference sensor signals

Publisher

London: Nature Publishing Group UK

Journal title

Scientific data, 2020-09, Vol.7 (1), p.291, Article 291

Language

English

Formats

Publication information

Publisher

London: Nature Publishing Group UK

More information

Scope and Contents

Contents

Using Radar it is possible to measure vital signs through clothing or a mattress from the distance. This allows for a very comfortable way of continuous monitoring in hospitals or home environments. The dataset presented in this article consists of 24 h of synchronised data from a radar and a reference device. The implemented continuous wave radar system is based on the Six-Port technology and operates at 24 GHz in the ISM band. The reference device simultaneously measures electrocardiogram, impedance cardiogram and non-invasive continuous blood pressure. 30 healthy subjects were measured by physicians according to a predefined protocol. The radar was focused on the chest while the subjects were lying on a tilt table wired to the reference monitoring device. In this manner five scenarios were conducted, the majority of them aimed to trigger hemodynamics and the autonomic nervous system of the subjects. Using the database, algorithms for respiratory or cardiovascular analysis can be developed and a better understanding of the characteristics of the radar-recorded vital signs can be gained.
Measurement(s)
vital signs • Respiratory Rate • heart function measurement • Stroke Volume • blood pressure
Technology Type(s)
24 GHz continuous wave radar • thoracic electrical bioimpedance (TEB) • electrocardiography • sphygmomanometry • impedance
Sample Characteristic - Organism
Homo sapiens
Machine-accessible metadata file describing the reported data:
https://doi.org/10.6084/m9.figshare.12613109...

Alternative Titles

Full title

A dataset of clinically recorded radar vital signs with synchronised reference sensor signals

Identifiers

Primary Identifiers

Record Identifier

TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7479598

Permalink

https://devfeature-collection.sl.nsw.gov.au/record/TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7479598

Other Identifiers

ISSN

2052-4463

E-ISSN

2052-4463

DOI

10.1038/s41597-020-00629-5

How to access this item